Before installing, check the nameplate on the retro motor and watch the power supply. Check if the speed reducer is intact. The requirements of the working environment should be placed in materials such as oil-free, acid, alkali, harmful gases, steam, radioactivity, etc.
2. When mounting the drive on the output shaft, the hammer is not allowed to be tapped, usually using the inner thread of the assembly jig and the shaft end, and the drive is pressed with a bolt, otherwise it is possible to cause damage to the internal parts of the speed reducer. No steel fixed coupling, due to improper installation of the type of coupling, it can cause unnecessary additional loads, resulting in early damage, and even cause the output shaft.
3. Due to the large load of the retrograde transmission of the worm gear gear reducing motor.
4. To completely remove pre-propelled, flanges, key surfaces, dirt, etc., should be careful when clearing the solvent is not allowed to immerse the oil seal when clearing the solvent.
5. The installation base of the reducing motor should be intensity, reliable stiffness, damping, anti-mutated base, gantry, etc., and the base must be dried, and there is no grease.
6. There are existing products that have the foundation of the installation flanges in installation.
7. The performance grade of the foundation spiral is 8.8.
8. The coupling between the retro motor work machine is recommended to use an elastic coupling.
9. Input, the output shaft is attached to the pocket, the brake, clutch, and the radial load on the gear should be as close as possible to the shaft shoulder.
10. The key hollow output shaft is coupled to the working machine shaft should be planted to prevent rust oil. It should be easily pushed or spirally pulled in, while the hollow output shaft of the tightening pan should not be oil. Oil, oil, and the other end can be contrained.
11. The input, output shaft and original motion of the reducer, the working axle should be strictly pair in the middle, and the requirements can reduce the vibration to reduce noise, extend the life of the bearings, and ensure the normal operation of the speed reduction motor.
12. To prevent accidents, the rotating site should be protected and covered according to safety requirements.
13. To ensure that the venting caps of each gear reducer should be installed correctly and ensure smooth ventilation. Guaranteed by the prescribed installation device to ensure convenient to the oil label, ventilation, drainage plug. After the installation is in place, the accuracy of the installation position should be fully inspected, and the reliability of each fastener is compressed, and it should be flexible after installation. The reducer is lubricated with the oil pool, and before running the user, the spline of the vent hole is required, replace the ventilator. Press different installation locations and open the height of the oil level line, from the oil level plug, from the oil level plug spill, screw the oil position, determine whether it is empty, The test operation is not less than 2 hours. The operation should be smooth, no shock, vibration, noise and leakage oil, and find abnormal removal.
14. When loading a moment, it should be installed in a state in which each other is free.
15. The installation lock must be firm and reliable, and it is not necessary to generate displacement in the work.
16. Be sure to install the grounding device to prevent electric shock accidents.