These are all customized products according to
customer's requirement. If needed, we can
provide custom sevice for you.
Check the oil level, whether it is qualified; install the oil level plug.
After cooling, the viscosity of the oil increases and it is difficult to drain the oil. The reducer should be changed at the operating temperature. Cut off the power to prevent electric shock! Wait for the reducer to cool down and there is no danger of burning!
Inject new oil of the same brand; the amount of oil should be consistent with the installation position; check the oil level at the oil level plug; tighten the oil level plug and breather; the reducer should still be warm when changing the oil; in the oil drain plug Place an oil pan below; open the oil level plug, breather and oil drain plug; drain all the oil; install the oil drain plug.
Cut off the power supply to prevent electric shock! Wait for the reducer to cool down; remove the oil level plug to check if the oil is full; install the oil level plug.
Cut off the power supply to prevent electric shock! Wait for the reducer to cool down; open the oil drain plug and take an oil sample; check the viscosity index of the oil; if the oil is obviously turbid, it is recommended to replace it as soon as possible.